In addition to the provisions of this chapter, the design and construction of foundations in flood hazard areas as established by, Foundation construction shall be capable of accommodating all loads in accordance with, Surface drainage shall be diverted to a storm sewer conveyance or other, Where quantifiable data created by accepted soil science methodologies indicate expansive, compressible, shifting or other questionable soil characteristics are likely to be present, the. The California Residential Code, 2019 Edition, promulgated by the California Building Standards Commission, 2525 Natomas Park Drive, Suite 130, Sacramento, California 95833-2936, based on the 2012 edition of the International Residential Code, published by the International Code Council 500 New Jersey Ave., NW, 6th Floor, Washington, D.C. 20001 . Building Permits and Inspection 827 7th Street, Room 102 (Map) Sacramento, CA 95814 311 or Outside of Unincorporated Sacramento County Areas: 916-875-4311 or e-mail You may also be interested in. Plasticity Index (PI) of 15 or greater, determined in accordance with ASTM D4318. Junk is defined as "any worn-out, cast-off, or discarded article or material which is ready for destruction or has been collected or stored for salvage or conversion to some use. All joints in membrane waterproofing shall be lapped and sealed with an adhesive compatible with the membrane. Sacramento County has many differentresidential accessory use classifications, ranging from guest houses to chicken coops. California Building Standards Code California Residential Code 2019 Based On The International Residential . O Box 903 Canberra ACT 2601 [email protected] New patient appointments: 916-734-5959 or 800-770-9261. (Title 24, Part 2, Section 2-3303 (a).) Refer to, Horizontal reinforcement requirements are for reinforcing bars with a minimum yield strength of 40,000 psi and, Table values are based on reinforcing bars with a minimum yield strength of 60,000 psi, Vertical reinforcement with a yield strength of less than 60,000 psi and/or bars of a different size than specified in the table are permitted in accordance with, NR indicates no vertical wall reinforcement is required, except for 6-inch-nominal, DR means design is required in accordance with the applicable. wdk450 said: With the "Lifetime" membership I bought for $1400 ($750 of that was "transfer fee" to Thousand Trails Corporate), I get . Solid walls or fences not exceeding three (3) feet, Fences constructed of chain link or similar woven material, not exceeding four (4) feet, or. Where splices are necessary in reinforcement, the length of lap splice shall be in accordance with Table R608.5.4. Wood sill plates shall be a minimum of 2-inch by 4-inch (51 mm by 102 mm) nominal lumber. Forty-mil (1 mm) polymer-modified asphalt. | Sacramento County. 0000004968 00000 n When you click on the link for the County Codes a new window will open displaying the site for the Sacramento County Codes. Please turn on JavaScript and try again. All such items should be stored inside a fully enclosed structure. <<8E80DF283E0A374986C9EDD50C4CE7D9>]>> Wall construction shall be in accordance with either Table R404.1.1(2), Table R404.1.1(3), Table R404.1.1(4), or a design shall be provided. Are youInterested in operating a Short-Term (Vacation)Rental on your property? Water & Sewer. Can I convert part of my home into an accessory dwelling unit? Yes. Furniture indoor furniture stored outdoor, damaged outdoor furniture, worn furniture, Containers (plastic tubs, crates, boxes, etc. Fences in interior yards shall not exceed seven (7) feet and may be located on a retaining wall not to exceed four (4) feet in height. . seepage 60, Multifamily Development Standards(Section 5.4.3.C.) Visit their website or view the Inspection Residential Information Booklet. The edges of the vapor retarder shall extend not less than 6 inches (152 mm) up the stem wall and shall be attached and sealed to the stem wall or insulation. Chapter 1 Scope and Application. Wood foundation systems shall be designed and installed in accordance with the provisions of this code. Nuisances are more specifically defined in the Sacramento County Code under section 16.18.401. (2) Exit doors shall be of the side swinging type. Alternative reinforcing bar sizes and spacings having an equivalent cross-sectional area of reinforcement per lineal foot of wall shall be permitted provided the spacing of the reinforcement does not exceed 72 inches in, Soil classes are in accordance with the Unified Soil Classification System and design lateral soil loads are for moist conditions without hydrostatic pressure. Website Policies & Use Allamakee, Black Hawk, Boone, Bremer, Buchanan, Buena Vista, Butler, Calhoun, Cerro Gordo, Cherokee, Chickasaw, Clay, Clayton, Delaware, Dubuque, Fayette, Floyd, Franklin, Grundy, Hamilton, Hancock, Hardin, Humboldt, Ida, Jackson, Jasper, Jones, Linn, Marshall, Palo Alto, Plymouth, Pocahontas, Poweshiek, Sac, Sioux, Dickinson, Emmet, Howard, Kossuth, Lyon, Mitchell, O'Brien, Osceola, Winneshiek, Androscoggin, Cumberland, Hancock, Kennebec, Waldo, Washington, Aroostook, Franklin, Oxford, Penobscot, Piscataquis, Somerset, Berrien, Branch, Cass, Kalamazoo, Macomb, Ottawa, St. Clair, St. Joseph, Alger, Charlevoix, Cheboygan, Chippewa, Crawford, Delta, Emmet, Iosco, Kalkaska, Lake, Luce, Mackinac, Menominee, Missaukee, Montmorency, Ogemaw, Osceola, Otsego, Roscommon, Schoolcraft, Wexford, Baraga, Dickinson, Iron, Keweenaw, Marquette, Aitkin, Big Stone, Carlton, Crow Wing, Douglas, Itasca, Kanabec, Lake, Morrison, Pine, Pope, Stearns, Stevens, Swift, Todd, Wadena, Becker, Beltrami, Cass, Clay, Clearwater, Grant, Hubbard, Kittson, Koochiching, Lake of the Woods, Mahnomen, Marshall, Norman, Otter Tail, Pennington, Polk, Red Lake, Roseau, St. Louis, Traverse, Wilkin, Broadwater, Golden Valley, Granite, Lake, Lincoln, Missoula, Ravalli, Sanders, Sweet Grass, Big Horn, Carbon, Jefferson, Judith Basin, Lewis and Clark, Meagher, Musselshell, Powder River, Powell, Silver Bow, Stillwater, Westland, Carter, Cascade, Deer Lodge, Falcon, Fergus, Flathead, Gallanting, Glacier, Madison, Park, Petroleum, Ponder, Rosebud, Teton, Treasure, Yellowstone, Beaverhead, Blaine, Chouteau, Custer, Dawson, Garfield, Liberty, McCone, Prairie, Toole, Wibaux, Adams, Banner, Chase, Cheyenne, Clay, Deuel, Dundy, Fillmore, Franklin, Frontier, Furnas, Gage, Garden, Gosper, Harlan, Hayes, Hitchcock, Jefferson, Kimball, Morrill, Nemaha, Nuckolls, Pawnee, Perkins, Phelps, Red Willow, Richardson, Saline, Scotts Bluff, Seward, Thayer, Webster, Boyd, Burt, Cedar, Cuming, Dakota, Dixon, Dodge, Knox, Thurston, Albany, Bronx, Cayuga, Columbia, Cortland, Dutchess, Genessee, Kings, Livingston, Monroe, Nassau, New York, Niagara, Onondaga, Ontario, Orange, Orleans, Putnam, Queens, Richmond, Rockland, Seneca, Suffolk, Wayne, Westchester, Yates, Clinton, Essex, Franklin, Hamilton, Herkimer, Jefferson, Lewis, St. Lawrence, Warren, Adams, Dickey, Golden Valley, Hettinger, LaMoure, Oliver, Ransom, Sargent, Sioux, Slope, Stark, Ashland, Crawford, Defiance, Holmes, Huron, Knox, Licking, Morrow, Paulding, Putnam, Richland, Seneca, Williams, Berks, Blair, Bradford, Cambria, Cameron, Centre, Clarion, Clearfield, Clinton, Crawford, Elk, Forest, Huntingdon, Indiana, Jefferson, Lackawanna, Lycoming, McKean, Pike, Potter, Susquehanna, Tioga, Venango, Warren, Wayne, Wyoming, Bennett, Custer, Fall River, Lawrence, Mellette, Shannon, Todd, Tripp, Bon Homme, Charles Mix, Davison, Douglas, Gregory, Jackson, Jones, Lyman, Beadle, Brookings, Brown, Campbell, Codington, Corson, Day, Deuel, Edmunds, Faulk, Grant, Hamlin, Kingsbury, Marshall, McPherson, Perkins, Roberts, Spink, Walworth, Carbon, Daggett, Duchesne, Rich, Sanpete, Uintah, Wasatch, Addison, Chittenden, Franklin, Orange, Washington, Windsor, Kenosha, Kewaunee, Racine, Sheboygan, Walworth, Ashland, Barron, Burnett, Chippewa, Clark, Dunn, Eau Claire, Florence, Forest, Iron, Jackson, La Crosse, Langlade, Marathon, Monroe, Pepin, Polk, Portage, Price, Rust, St. Croix, Taylor, Trempealeau, Vilas, Wood, Bayfield, Douglas, Lincoln, Oneida, Sawyer, Washburn, Campbell, Carbon, Hot Springs, Johnson, Natrona, Sheridan, Uinta, Weston, One No. LOCATIONS BY COUNTY, INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO UNHEATED SLAB-ON-GROUND STRUCTURE, INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO HEATED STRUCTURE, Foundations that adjoin frost-protected shallow foundations shall be protected from frost in accordance with, Vertical wall insulation and horizontal insulation of frost-protected shallow foundations that adjoin a slab-on-ground foundation that does not have a monthly mean temperature maintained at a minimum of 64F (18C) shall be in accordance with Figure R403.3(3) and, Where a frost-protected shallow foundation abuts a structure that has a monthly mean temperature maintained at a minimum of 64F (18C), horizontal insulation and vertical wall insulation shall not be required between the frost-protected shallow foundation and the adjoining structure. | Contact Us Conducts field inspections on permitted work to assure that the projects comply with approved plans and all applicable Building Codes. 829 21 Development Standards are specific regulations, codes, or policies that dictate how you may develop a property. Insulation requirements are for protection against frost damage in heated buildings. Can I build a fence in my front yard or side-street yard? City of Sacramento Community Development Department A Book Report prepared by the Sacramento Association of Building Officials . ASTM A996 bars produced from rail steel shall be Type R. In buildings assigned to. Policies|Accessibility|Social Media| Website Feedback 2013 - 2022 City of Sacramento, Master Plan & Production Permit Automation, Statewide Community Infrastructure Program, Skip to Left Navigation / Tab to View Content, 2019 California Building Code Change Summary (Part 2, Volumes 1 & 2), 2019 California Residential Code Change Summary (Part 2.5), 2019 California Electrical Code Change Summary, 2019 California Mechanical Code Change Summary (Part 4), 2019 California Plumbing Code Change Summary (Part 5), 2019 California Energy Code Change Summary (Part 6). Wood columns shall be not less in nominal size than 4 inches by 4 inches (102 mm by 102 mm). Exposed earth is covered with a continuous Class I vapor retarder. | Contact Us | Sacramento County. Fences exceeding these heights may be allowed with the issuance of a Minor Use Permit. Subject: PLNP2015-00267. Commercial Development Standards(Section 5.5.2.A. Interior covering. Sixty-mil (1.5 mm) flexible polymer cement. Extended below the frost line specified in Table R301.2.(1). Residential Accessory Uses Sacramento County has many different residential accessory use classifications, ranging from guest houses to chicken coops. The 2021 IBC contains many important changes such as: Puzzle rooms (escape rooms) are now defined and regulated as special amusement areas, requiring compliance with Section 411 and special means of egress requirements. Are people that scavenge from my recycling bin in violation of the law? An Accessory Dwelling Unit, commonly known as a "granny-flat" or "mother-in-law's quarters" is allowed up to 850 square-feet if one bedroom or 1,000 square-feet if two bedrooms or more in most zones. (a) General. Per California fireplace hearth dimensions code as published on UpCodes, if the firebox, or the opening of the fireplace, is less than 6 feet square, then the requirement is that the hearth. (Title 24, Part 2, Section 2-3303 (a).) The law includes specific requirements for the basis for a local amendment, how the amendment language and documents must be prepared, and how the amendment must be filed with either CBSC, the Department of Housing and Community Development or other state agencies as required. Can I attach an accessory dwelling unit to my home? (1) and Figure R608.5.4(1). Soils meeting all four of the following provisions shall be considered expansive, except that tests to show compliance with Items 1, 2 and 3 shall not be required if the test prescribed in Item 4 is conducted: Footings for wood foundations shall be in accordance with Figures, For buildings where the monthly mean temperature of the building is maintained at a minimum of 64F (18C), footings are not required to extend below the frost line when protected from frost by insulation in accordance with Figure R403.3(1) and Table R403.3(1). Sacramento County Code - A set of laws that consists of all of the regulatory and penal ordinances and certain of the administrative ordinances codified pursuant to Sections 25126 to 25130, inclusive, of the Government Code of the state. | Report a Problem Residential Building Code: The California Building Code (CBC) 2019 is adopted. In most cases, manufactured homes are allowed as either a primary residence or an accessory dwelling unit, subject to the standards of Sacramento County Zoning Code Section 3.5.1.G., which can be found inChapter 3 of the Zoning Code.. WebInternational Residential Code 2018 (IRC 2018) Change Code. It looks like your browser does not have JavaScript enabled. Typical single-family residential homescan be up to 30 feet tall. The Carbon Monoxide Poisoning Prevention Act - Senate Bill SB 183 - requires all single-family homes with an attached garage or a fossil fuel source to install carbon monoxide detectors within the home by July 1, 2011. PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION, The minimum width, W, and thickness, T, for, Where the slab is not cast monolithically with the footing, No. Code of Regs., Title 24). Residential Accessory Structures webpage for more information., Yes. 0000001826 00000 n Please contact the Office of Planning and Environmental Review atsacplan@saccounty.govfor information regarding specific regulations or before submitting an application.Alternatively, you mayschedule an appointmentwith the Planning front counter of the Building Assistance Center.. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 degree = 0.0175 rad. 0000001513 00000 n Ordinances On File 2022 Ordinances amending the 2022 edition of Title 24 2019 1001 45th Street Sacramento, CA 95819. trailer Can I convert my garage into an office or bedroom? Code Ann. For SI: 1 inch = 25.4 mm, C = [(F) - 32]/1.8. Neighbor fences are not required. Code Development Committee . The Sacramento County Zoning Code is subjected to periodic review and revisions. Fences in the AG or AR zone may be seven feet at all property lines. Part III Building Planning and Construction. | Contact Us The development standards provide information such as required building setbacks, height limitations, lot coverage, landscaping requirements, and parking ratios. Is it legal to live in a Recreational Vehicle (RV) on residential property? Grout used for bedding precast foundations placed upon. The maximum gap between noncontact parallel bars at a lap splice shall not exceed the smaller of one-fifth the required lap length and 6 inches (152 mm) [See Figure R608.5.4(1)]. Shower Sizing Different municipalities may impose minimum shower sizes, but many stick to the California Building Code. MA 02120 Apartment for rent Request a tour Request to apply 3 available units in this apartment building Full building details Date available: Fri Sep 1 2023 Type: Apartment . It looks like your browser does not have JavaScript enabled. Fences do not indicate legal property lines and are frequently erected without regards to legal property lines. Backfill shall not be placed against the wall until the wall has sufficient strength and has been anchored to the floor above, or has been sufficiently braced to prevent damage by the backfill. Residential accessory structures are typically required to be 16 feet tall or less. FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH, Use of pier and curtain wall foundations shall be permitted to support. Pursuant to Sacramento County Zoning Code Section 5.2.5.B., fences in the front yard (i.e. Yes. 0 Electrical Mechanical Plumbing Propane Electrical Handouts Residential Generator Checklist (PDF) Kitchen / Bath Lighting (PDF) Lighting T-24 Energy LTG Forms (Non-Residential) (PDF) Residential Electrical Service (PDF) Solar System Checklist (PDF) Code Handouts Residential Commercial Residential Code Handouts Addressing (PDF) Website Policies & Use Check your property to look up ADU zoning and calculate ROI. Part I Administrative. Our goal is to maintain and improve property values and the quality of life for residents, visitors and business owners.We work to achieve voluntary compliance through notification and education. Sacramento City Planning Offices. Single Floor in accordance with DOC PS 1 or DOC PS 2. Residential Accessory Structures webpage. NR indicates no vertical reinforcement is required. The finished ground level of the under-floor space shall be equal to or higher than the outside finished ground level on at least one side. Website Policies & Use | Sacramento County. Approved 6/1/2021. startxref It is a violation of the zoning code to have junk and rubbish on the property whether screened from view or not. California's first-in-the-nation GREEN building code. When adding additional surfaced parking in the front or side-street yard of your residence, the following requirements must be met: Yes. Chapter 3 Building Planning. Footings shall be stepped where it is necessary to change the elevation of the top surface of the footings or where the slope of the bottom surface of the footings will exceed one unit vertical in 10 units horizontal (10-percent slope). For SI: 1 inch = 25.4 mm, 1 pound per square inch = 6.895 kPa. Wood foundations in Seismic Design Category D 0, D 1 or D 2 shall be designed in accordance with accepted engineering practice. (1) and Figure R608.5.4(1). Structural I Sheathing (Exposure 1). zoning starts with an AG, AR, A,or RD code and doesn't have any additionalcode in parentheses. As of January 1, 2020, the City of Sacramento is requiring all new plan review and permit applications to comply with the 2019 California Building Standards Codes and applicable City Code Amendments. 100 Parks St #29, Duxbury, MA 02332 is a 2 bedroom, 2 bathroom condo built in 1984. 200 sieve (75 m), determined in accordance with ASTM D422. The bottom surface of footings shall not have a slope exceeding one unit vertical in 10 units horizontal (10-percent slope). The top surface of footings shall be level. Please contact us at sacplan@saccounty.gov to verify height requirements in all zoning districts. Ordinances amending the 2022 edition of Title 24, Ordinances amending the 2019 edition of Title 24, Ordinances amending the 2016 edition of Title 24. The storage of junk, garbage, and rubbish within view ofthe public right-of-way is in violation of additional nuisance laws beyond simple storage of junk and rubbish as prohibited in the zoning code. Wall height shall not exceed 8 feet (2438 mm). The use of nonstructural fibers shall conform to ASTM C1116. The nominal maximum size of coarse aggregate shall not exceed one-fifth the narrowest distance between sides of forms, or three-fourths the clear spacing between reinforcing bars or between a bar and the side of the form. SVABO members are encouraged to purchase the publication in preparation for the 2019 California Building Code as the . Duplexes or halfplexes are allowed by right in the RD-10 zone, the RD-15 through RD-40 zones, and in the RM-2 zone. | Contact Us 0000000716 00000 n seepage 42. Title 12: Streets and Sidewalks of the Sacramento County Code governs public streets, intersections, and sidewalks including penalties and enforcement. 2022 California Code Adoption for Local Jurisdictions webinar via YouTube(opens in new window). It shall be unlawful for any person to store or keep, or permit others to store or keep junk on their property. Local jurisdictions are urged to consult CBSC's Guide for Local Amendments of Building Standardsbefore pursuing amendments to Title 24 building standards. Architectural and Transportation . Find other city and county zoning info here at ZoningPoint. A duplex or halfplex is allowed by right on corner lots in the RD-5 zone. The sump shall be not less than 24 inches (610 mm) in, In areas where a high water table or other severe soil-water conditions are known to exist, exterior foundation. Steel columns shall be not less than 3-inch-, The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a. Semi-open fencing, such as picket fencing or chain link fencing, cannot exceed four feet in height. A permit is required for projects such as new construction, additions, remodeling, and repairs to electrical, mechanical, and plumbing systems. It looks like your browser does not have JavaScript enabled. 0000002716 00000 n Table values are based on reinforcing bars with a minimum yield strength of 60,000 psi. A 6-mil-thick (0.15 mm) polyethylene film shall be applied over the below-, The space between the excavation and the foundation wall shall be backfilled with the same material used for footings, up to a height of 1 foot (305 mm) above the footing for well-drained sites, or one-half the total back-fill height for poorly drained sites. This includes, but is not limited to: scrap metals or other scrap materials on any lot or parcel, or any portion thereof, in any zone other than a heavy industrial zone. PRESUMPTIVE LOAD-BEARING VALUES OF FOUNDATION MATERIALS. Do you plan to includea sleeping area in youraccessorystructure? Mobile homes that have or had axles and wheels but are designed to be detached are considered permanent dwellings and do not have the same regulations as RVs. Can I put a tiny home on my property? | Report a Problem The occupancy must cease within 30 days of the issuance of the final building permit. Sixty-mil (1.5 mm) solvent-free liquid-applied synthetic rubber. In other words, a nuisance interferes with the comfortable enjoyment of life or property. View the 2022 Information Bulletin regarding local amendments: Additionally, CBSC, in collaboration with the International Code Council, California Building Officials (CALBO), and Stuart Tom, JAS Pacific president and ICC Board member, developed the following webinar on the code adoption process for local jurisdictions. For residential parcels that are 15,000 square feet in size or greater, the surfacing may be permeable. 3 or larger vertical dowels with standard hooks on each end shall be installed at not more than 4 feet (1219 mm) on center in accordance with Figure R403.1.3, Detail 2. Part III Building Planning and Construction, R406 Foundation Waterproofing and Dampproofing, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances, and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T RECOMMENDED PROCEDURE FOR WORST-CASE TESTING OF ATMOSPHERIC VENTING SYSTEMS UNDER N1102.4 OR N1105 CONDITIONS 5ACH, Appendix U Solar-Ready ProvisionsDetached One- And Two-Family Dwellings, Multiple Single- Family Dwellings (Townhouses), Appendix W Areas Protected by the Facilities of the Central Valley Flood Protection Plan, The provisions of this chapter shall control the design and construction of the foundation and foundation spaces for buildings. For more information, visittheBuildingPermits andInspection Home page.. The RV must be operational and currently registered to the home. | Connect with Us Examples include: New homes and buildings Room additions Enclosures and carports Decks and patio covers Garage conversions Landscape irrigation Retaining walls Window replacements Water services For instance, according to the city of Berkeley, your shower needs to be at least 1,024 square inches, which is equivalent to a square space with 32-inch sides. Condo for rent at 163 Hurley Ave. Hurley Crossing is an apartment community located in Ulster County and the 12401 ZIP Code. CMID maintains expertise in construction management, inspection and material testing. Request For A . Joints of the vapor retarder shall overlap by 6 inches (152 mm) and shall be sealed or taped. Please contact Building Permits and Inspections at (916) 875-5599 for information regarding necessary permits. Chapter 5 of the Sacramento County Zoning Code contains most of the Development Standards for structures and development within Sacramento County. REQUIREMENTS OF LAW: State laws authorize local governments to enact ordinances making building standards amendments to the California Building Standards Code (Cal. Insulation materials shall provide the stated minimum. What are the development standards for commercial and industrial properties? Please contact the Office of Planning and Environmental Review to obtain information regarding any recent Code revisions, or to obtain the most recent copy of the Zoning Code. Accessory Structures in Agricultural and Agricultural Residential Zones(Section 5.3.2.C.) See Figure R403.3(2) or Table R403.3(2) for Air Freezing Index values. Any trailer type RVs that are parked on the street shall not be detached from the tow vehicle while parked there. | Report a Problem Vertical insulation shall be expanded polystyrene insulation or extruded polystyrene insulation. 0000008268 00000 n Instead of a complete geotechnical evaluation, where top or subsoils are compressible or shifting, they shall be removed to a depth and width sufficient to ensure stable moisture content in each active zone and shall not be used as fill or stabilized within each active zone by chemical, dewatering or presaturation. Building codes are a set of regulations that builders and architects must follow when constructing or renovating a building. Stay-in-place forms constructed of rigid foam plastic shall be protected on the interior of the building as required by, Termite protection. | Sacramento County. MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH NOMINAL FLAT, For SI: 1 foot = 304.8 mm; 1 inch = 25.4 mm; 1 pound per square foot per foot = 0.1571 kPa, MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH (203 mm) NOMINAL FLAT, MINIMUM VERTICAL REINFORCEMENT FOR 10-INCH NOMINAL FLAT, For SI: 1 inch = 25.4 mm; 1 foot = 304.8 mm; 1 pound per square foot per foot = 0.1571 kPa, MINIMUM VERTICAL WALL REINFORCEMENT FOR 6-INCH WAFFLE-GRID, MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH WAFFLE-GRID, MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH (152 mm) SCREEN-GRID, MINIMUM VERTICAL REINFORCEMENT FOR 6-, 8-, 10-INCH AND 12-INCH NOMINAL FLAT, MINIMUM SPACING FOR ALTERNATE BAR SIZE AND/OR ALTERNATE.
What Is The Darkest Joke You've Ever Heard, Articles S